Free whitepaper

Healthspan trial endpoint playbook

A playbook for healthspan trial endpoints: what regulators accept today, the five intrinsic capacity domains, instrument choice, biomarker timepoints and sample custody.

Inside the whitepaper:

  • What regulators accept today
  • The five intrinsic capacity domains
  • Choosing instruments
  • Planning biomarker timepoints
  • Sample custody

Mahalo Health · 2026-10-14

What regulators accept today

Start from where things stand in late 2026:

  • There is no FDA-approved indication for aging, no validated aging biomarker and no accepted regulatory endpoint for aging (Reagan-Udall Foundation meeting summary, July 2026). The May 2026 meeting described itself as a discussion, not policy.
  • FDA Chief Scientist Steven Kozlowski said no aging biomarker has validated or reasonably-likely surrogate status, and that functional outcomes are closer to patient benefit (morning transcript).
  • FDA participants pointed to existing routes: IND meetings, biomarker qualification, clinical outcome assessment development and established disease pathways.
  • The ARPA-H working group's consensus statement to FDA (18 May 2026) says intrinsic capacity is not a validated surrogate and does not endorse a single global composite as a default primary endpoint. It recommends domain composites as endpoints and multi-domain secondary outcomes for now.
  • ARPA-H's PROSPR program funds teams using biomarkers as surrogates in trials of one to three years (ARPA-H, February 2026). That is research toward qualification, not an accepted endpoint.

The practical reading is to lead with functional measures that regulators already understand, treat biomarkers as supporting or exploratory unless you have a qualification route, and raise endpoint choice early.

Where the evidence stands

  1. Accepted today

    Existing routes: IND meetings, COA development, disease pathways

  2. Recommended near term

    IC domain composites and multi-domain secondary outcomes

  3. Not yet validated

    Aging biomarkers as surrogates; single global IC score

Where the evidence stands

The five intrinsic capacity domains

Intrinsic capacity comes from WHO's ICOPE approach. The ICOPE handbook uses a nine-item screening step followed by full assessment of flagged domains (Leung et al., BMC Geriatrics 2022). ICOPE screening is designed for primary care, not for detecting change in a trial.

The ARPA-H consensus uses five trial domains: locomotor, cognitive, psychological, sensory and vitality. ICD-11 includes "decline in intrinsic capacity" as a code.

Five intrinsic capacity domains (ARPA-H consensus, 2026)

  1. Locomotor

    Gait speed, SPPB

  2. Cognitive

    MoCA, DSST or Trail Making

  3. Psychological

    PHQ-9, GAD-7

  4. Sensory

    Visual acuity, audiometry

  5. Vitality

    Grip, respiratory function, nutrition, fatigue

Five intrinsic capacity domains (ARPA-H consensus, 2026)

Choosing instruments

The Core Trial Battery v1.0 in the ARPA-H consensus statement suggests these Tier-1 measures:

  • Locomotor: gait speed over 4 to 6 metres and SPPB, with continuous scoring preferred.
  • Cognitive: MoCA plus the Digit Symbol Substitution Test or Trail Making.
  • Psychological: PHQ-9 and GAD-7, with WHO-5 optional.
  • Sensory: visual acuity and pure-tone audiometry.
  • Vitality: grip strength, respiratory function, nutrition and fatigue.

Tier-2 options include the six-minute walk test, chair rise, contrast sensitivity, speech-in-noise and olfaction. The statement does not recommend the MMSE.

When you choose, check for:

  • Ceiling effects in younger-old, high-functioning adults.
  • Practice effects on repeated cognitive tests, and whether alternate forms exist.
  • Licensing, translation and validation status for each language and region.
  • Whether the measure can be done at home, in clinic or both, and whether those versions are comparable.

Planning biomarker timepoints

FDA qualifies a biomarker for a specific context of use, and the qualification plan must describe the analytical method and its performance characteristics (About Biomarkers and Qualification). The field has a framework for biomarkers of aging (Moqri et al., Cell 2023) but no consensus on validation (Moqri et al., Nature Medicine 2024). A preliminary XPRIZE Delphi opposed epigenetic clocks as a single biomarker.

For each biomarker, write down in the protocol:

  • Its role: primary, secondary, supporting or exploratory, and the context of use.
  • Baseline timing, including whether you take repeat baselines.
  • Follow-up timepoints aligned with functional assessments, so the two can be analysed together.
  • Pre-analytical conditions: fasting, time of day, recent exercise and medication timing.
  • The assay and version, and what happens if the lab or assay changes mid-study.

Sample custody

A biomarker value is only as reliable as its sample history. The ISBER Best Practices cover collection, processing, storage and documentation. ICH E6(R3) asks for record integrity and traceability and for fit-for-purpose computerized systems (FDA guidance, September 2025). For each sample, record:

  • Collector, time, place and collection conditions.
  • Time to processing, method and operator.
  • Storage location, temperature history and freeze-thaw events.
  • Aliquot lineage from parent to child tubes.
  • Assay batch and run.
  • The consent version covering banking and future use.

On Mahalo Research, eConsent records biospecimen banking and future-research permissions separately with the exact consent version, and registries run at-home biosample collection on the same scheduling and reminder rails as other study activities. Mahalo Research also tracks sample kits, aliquot lineage and the custodian timeline for each specimen.

Sample custody record

  1. Collect

  2. Process

  3. Store

  4. Aliquot

  5. Assay

Sample custody record

Running the schedule

A multi-domain battery with biomarkers and home visits is a scheduling problem. On Mahalo Research:

  • eCOA and ePRO use delivery times, grace periods and expiration windows. Licensing, translations and validation are confirmed per deployment.
  • Wearable and device data keeps source, device, timestamp, units, capture mode and sync context. Devices are confirmed per deployment.
  • Digital biomarkers are handled as governed time-series data with source metadata and quality flags.
  • Sentinel supports smartphone assessments of gait, balance and functional mobility, including Timed Up & Go.
  • Mahalo Intelligence drafts study parameters from the protocol for human review. A deterministic compiler then derives study artifacts, and the audit history records who approved each step.
  • In the Workbench, analysis runs on versioned datasets with lineage, and outputs leave only through egress review.
  • Core Trial Battery instruments, including SPPB, MoCA and EQ-5D-5L, are delivered under Mahalo Research's existing licences.
  • Study exports can be mapped to CDISC SDTM.

The SINGER multidomain geriatric trial at NUS and NUHS ran on Mahalo Research (customer story), and the PREDICT longitudinal depression cohort at IMH uses eCOA and ePRO over five years with a 36-month extension (customer story).

Endpoint checklist

  • Primary endpoint is a functional measure or domain composite, not a global IC score.
  • Each instrument has a confirmed licence, translation and validated mode.
  • Repeat baselines and alternate cognitive forms are in the schedule.
  • Each biomarker has a stated role and context of use.
  • Biomarker timepoints line up with functional assessments.
  • Pre-analytical conditions are written in the protocol and captured at collection.
  • Every sample links to its aliquots, assay run and consent version.
  • Endpoint strategy is on the agenda for an early IND meeting.

References

Frequently asked questions

Who is this playbook for?
Principal investigators, study managers and statisticians planning healthspan or geroscience trials.
Does it recommend a primary endpoint?
It follows the May 2026 ARPA-H consensus statement to FDA, which favours intrinsic capacity domain composites over a single global score and does not treat intrinsic capacity as a validated surrogate.
Does it cover biomarkers?
Yes. It covers biomarker roles, context of use, timepoints, pre-analytical conditions and sample custody records.